Electrolyzer
parameter
|
Rated hydrogen production | 1000±5% Nm³/h(continuous, stable and adjustable) |
Rated oxygen production | 500±5% Nm³/h(continuous, stable and adjustable) | |
Rated capacity electricity consumption
|
≤4.6kWh/Nm³H2(electrolytic cell energy consumption) | |
System operation pressure | 1.6MPa±5%(In 30%~110% load range) | |
Load regulation range
|
30~110% | |
hydrogen purity | ≥99.7%(Electrolyzer Outlet,Before hydrogen purification) | |
Oxygenpurity |
≥98.5%(Electrolyzer Outlet)
|
|
System efficiency | ≥90%(After heat recovery) | |
Lifetime
|
80000h~100000h(Subject to conditions of use) | |
Purification
system
parameter
|
Purification system capacity |
1000±5% Nm³/h(continuous, stable and adjustable)
|
Hydrogen purity
|
≥99.9997%(After purification) | |
Hydrogen pressure at Purification outlet | 1.5MPa±5%(In 30%~110% load range) | |
Oxygen content | ≤5 ppm | |
Dew point
|
Dew point≤-65℃ | |
Operating
Conditions
|
Operation Temperature
|
-30℃ to 45℃(Container temperature) |
Operation Humidity | 5~95%RH | |
Altitude
|
≤ 2000m | |
Main supply voltage | 10kV, 50Hz, three phase | |
Auxiliary supply voltage | 380V, 50Hz, three phase |